ODU. LIGHT. IDU. DISPLAY.
(1)>16.time. P4! DC voltage over-high voltage protection
(2)>17.time. P5! IPM Over-high temperature, protection
(3)>18.time P6! Discharge temperature overheat protection
(4)>19.time. P7! Cooling indoor coil anyi - freezing protection
(5)>20.time. P8! cooling outdoor coil overheat protection
(6)>21.time. P9! Heating indoor coil overheat protection
(7)>22.time. PC! Cooling outdoor ambient temperature over-high protection
(8)>23.time. PH! Heating outdoor ambient temperature over-high protection
Voltas Inverter split airconditioner ka error code voltas
![]() |
Service Code ERROR Definition Releted Part Check Point
E 1
No / Low water Supply Water Inlet Valve
-Water inlet hose Filter
-Water pressure from tank
-Water Sensor Air Hose position
E 2
No Drain Drain assly
Drain Motor
-Drain housing blocked
-Drain Motor
-Water Sensor Air Hose position
E 3
Un-balance Checker Switch
-Loundry uneven
-Uneven floor
-WM feet balance
E 4
Water Over flow Water Inlet Valve
Pressure Sensor
-Water inlet hose Filter
-Water Sensore Air Hose position
E 5
Water Lavel Sensor
Water Inlet Valve
Pressure Sensor
Control PCB
-Water inlet hose Filter
-Water Sensor Air Hose position
-Excess laundry
- Wire Harness connection
E 6
Safety Switch Door Lid safety switch
Control PCB
-Contact point of safety switch
-Wire Harness of PCB
Ea Voltage Issue Main PCB
Voltas beko washing machine front load
out light. IDU Display. (1)>25 time EE! Indoor machine EE fault.
(2)>26 time. E1! Indoor fan fault
(3)>27 time. E2! Indoor fan zero-crossing detection abnormal
(4)>28 time. E3! Indoor coil fault and sensor fault
(5)>29 time. E4! Indoor ambient temperature sensor fault
(6)>01 time. E0! Outdoor EE fault
(7)>02 time. E6! Indoor and outdoor machine communication fault
(8)>04 time. F1! Compressor starting abnormal (phase fault,reverse)
(8)>05 time. F2! Compressor out-of-step fault
(9)>06 time. F3! IPM module fault
(10)>07 time. F4! Compressor shall road fault
Voltas inverter ac error code
top social